3U/6kW, ultra-high power density
N69200 is designed with high power density. Power of 19” 3U chassis can be up to 6kW. The volume and weight are half of traditional electronic loads. Compared with traditional electronic loads with the same power, N69200 is smaller in size and lighter in weight.

Parallel connection for power extension
N69200 supports parallel connection. When the load power needs to be increased, models with the same voltage specification can be connected in parallel (master + master, master + slave) to achieve the required current and power. When using N69200, users only needs to set current on the master. The slave current will be distributed automatically, which simplifies the operation steps.

Multiple operation modes
N69200 supports four normal working modes: CC, CV, CP, and CR. In order to cope with the change of load characteristics in the actual test process, N69200 has also been developed with CV+CC, CR+CC, CV+CR, CP+CC four combined working modes. For example, CR+CC is suitable for the startup test of power supply to prevent overcurrent protection when the power supply is turned on. CV+CR can replace the setting application of Von point. CV+CC can simulate the working mode transition process of battery charging. Users can choose different working modes for test according to their actual situation.

High speed dynamic mode, with dynamic frequency sweep
N69200 has a high-speed dynamic mode. The dynamic characteristics of the DC power supply can be tested by simulating the dynamic load behavior of the power supply through the dynamic mode. N69200 provides dynamic frequency sweep and programmable dynamic mode up to 30kHz, including CCD constant current dynamic, CVD constant voltage dynamic, CRD constant resistance dynamic, and CPD constant power dynamic. Programmable dynamic load mode allows setting of high/low range, rise/fall slew rate, pulse width and operation mode. The voltage and current sampling rate of dynamic frequency sweep mode is 500kHz. It supports linearly changing the frequency of the load current. Frequency is up to 30kHz. This mode can measure the peak voltage Vpk+, valley voltage Vpk- and occurrence frequency points of the DUT during the dynamic frequency load change process.

Charge & discharge test
Users can set different conditions on the front panel to meet their test demands. For example, when battery voltage is lower than initial voltage, N69200 internal counter will start counting. The counter will stop working until the battery voltage drops to cut-off voltage.

OCP( over current protection) test
During OCP test, N69200 will load under CC mode and check whether the DUT voltage is lower than cut-off voltage. If lower, N69200 will record the present loading current as the test result and shut the input to stop the test. If the DUT voltage is higher than cut-off voltage, N69200 will increase the loading current until the DUT voltage is lower than cut-off voltage or it reaches the Max. loading current.
Equivalent Series Resistance( ESR) test (Optional)