Multi optional operating modes
N62100 series not only supports regular CC/CV/CP/CR operating modes,but also supports CV+CC,CR+CC,CV+CR,CP+CC,combined operating modes to meet with the variation of load characteristic during the actual test procedure. For example, CR+CC mode can be used for power supply starting up test to avoid over-current protection when power-on;CV+CR mode can be used for replacing Von-point setting application;CV+CC mode can be used for simulating the battery charging operating mode switching process,users can choose the different operating modes according to the actual test application.

LED simulation function
LED driving source is a kind of constant current source,the output current should be stabilized and not higher than LED rated current to avoid accelerating LED aging damage. LED is equivalent to series connection between Resistance Rd and Voltage source Vf, the tangent line of the I-V curve at the operating point (V0, I0) is equivalent to the actual LED nonlinear I-V curve. N62100 series supports LED simulation function, users need to set LED rated current, LED operating voltage, resistivity parameters to simulate the LED loading characteristics during LED power supply test process.

Overcurrent protection test function
The up slope current is used to test whether the voltage of DUT reaches the cut-off point, so as to confirm whether the OCP protection of the power supply is normal, and test the output response of the DUT under over-current.